Solar Inverter Size Calculator: Size Panels, Inverter & Battery

Enter your monthly electricity units (or daily kWh), peak simultaneous home load, local sun hours, and outage backup hours to get an instant solar panel, inverter kW, and battery bank estimate.

Adjust your monthly bill and evening backup needs — the sizing card updates immediately.

1. Electricity usage & peak load

2. Sunlight & panel rating

3. Outage backup & battery storage

Quick answer Size your solar panels from monthly units (Monthly kWh ÷ 30 ÷ Sun Hours ÷ 0.80), size your inverter kW from simultaneous appliances + motor surge (typically 3 kW, 5 kW, 8 kW, or 10 kW), and size your battery bank strictly from outage hours (0 batteries for pure on-grid, 48 V lithium or tubular for hybrid).
Solar panels daytime charging Grid power when available Inverter + charger Battery stores the power Your home fans · lights · fridge
Solar and grid charge the inverter. The inverter fills the battery and runs your home. In a power cut, the battery feeds the inverter and your home stays on.

How solar + hybrid inverter sizing works

Unlike a basic battery inverter that only handles power cuts, a solar system solves two separate engineering questions at once: daily energy (kWh) to offset your electricity bill, and instantaneous power (kW) so the inverter never trips when appliances start.

  • Step 1 — Daily kWh demand: Divide your 12-month average monthly electricity units by 30. A 450-unit monthly home averages 15 kWh/day.
  • Step 2 — Panel array (kWp): Divide daily kWh by your site's Peak Sun Hours multiplied by ~0.80 (which captures heat derating on hot roofs, dust, DC wiring drop, and MPPT conversion losses).
  • Step 3 — Inverter rating (kW / kVA): Choose a standard inverter rating at least 25% above your peak running load (so an AC + fridge start does not cause an overload fault), while keeping the panel array below the inverter's maximum PV input wattage and Voc ceiling.
  • Step 4 — Battery storage (kWh): Only size storage for evening load during blackouts or peak tariff windows—unless you are completely off-grid. See hybrid vs on-grid vs off-grid inverters for when zero batteries makes financial sense.

Peak sun hours by region

"Sun hours" does not mean daylight hours from sunrise to sunset. One Peak Sun Hour (PSH) equals an hour of solar irradiance averaging 1,000 W/m². That single multiplier determines why a 5 kW array produces ~600 units/month in Lahore or Jaipur versus ~320 units/month in London.

Region Avg. Peak Sun Hours Est. output per 1 kWp / month 5 kWp array monthly yield
Pakistan / Gulf / Dry Plains5.0 – 5.5 hrs120 – 132 units~600 – 660 units
India / Nigeria / Australia4.5 – 5.2 hrs108 – 125 units~540 – 625 units
Philippines / SE Asia / Florida4.0 – 4.5 hrs96 – 108 units~480 – 540 units
UK / Northern Europe2.5 – 3.0 hrs60 – 72 units~300 – 360 units

Panel kW vs inverter kW (the DC-to-AC ratio)

New buyers often assume a 5 kW inverter must have exactly 5 kW of panels. In reality, solar modules rarely hit full STC nameplate output because rooftop cells run 25–35°C hotter than lab test conditions. Sizing your panel array 1.1× to 1.4× larger than the inverter rating increases early morning, late afternoon, and winter production dramatically. Read our real rooftop case study: 4 kW SolarMax hybrid running a 6.45 kW array.

Worked example: offsetting a 450-unit monthly home bill

A home consuming 450 units/month (15 kWh/day) in a 4.8-sun-hour climate needs 15 ÷ (4.8 × 0.80) = 3.91 kWp of solar panels—achieved cleanly with 7 × 585 W modules (4.10 kWp). If that household wants to run a 1.5-ton inverter AC plus fridge and fans simultaneously during the afternoon, pairing that array with a 5 kW 48 V hybrid inverter prevents overload trips and leaves spare PV capacity to expand later.

Frequently asked questions

How big a solar inverter do I need for my electricity bill?

Start with monthly units divided by 30 for daily kWh, then divide by (peak sun hours × 0.80 system efficiency). For example, 450 units/month (15 kWh/day) at 5 peak sun hours needs ~3.75 kWp of panels paired with a 5 kW hybrid inverter if you also run heavy loads like a 1.5-ton inverter AC.

Can my solar panels have more watts than the inverter rating?

Yes, within the inverter MPPT voltage and current limits. Most grid-tied and hybrid inverters work best with a 1.2 to 1.4 DC-to-AC array ratio because panels rarely reach 100% lab output in heat and haze. See our 4 kW SolarMax + 6.45 kW array project note for a working example.

Should I choose an on-grid or hybrid solar inverter?

Choose a pure on-grid inverter only if utility outages are rare and net metering is approved; it shuts down during power cuts for safety. Choose a hybrid inverter if you need battery backup during load-shedding alongside solar bill offset.

What battery voltage works best for a 5 kW solar inverter?

Virtually all 5 kW hybrid solar inverters require a 48 V DC battery bank (four 12 V tubular batteries in series or one 48 V / 51.2 V LiFePO4 pack). Running 5 kW on 12 V or 24 V pushes excessive current through the cables.

How many 585W panels fit a 5 kW hybrid system?

A 5 kW hybrid residential build commonly uses 8 to 10 panels rated around 580–585 W (4.6 to 5.85 kWp), generating roughly 550 to 700 units per month in a 5-sun-hour climate depending on seasonal shade and roof tilt.

Recalculate your solar setup ↑
Engr. Syed Farrukh Anwar

Written by

Registered Professional Electronics Engineer (PEC ELECTRO/15141)

A licensed practitioner with boots-on-the-ground experience across South Asia and the Middle East, designing and commissioning high-yield solar arrays and backup systems for some of the harshest thermal environments on Earth. InverterWise exists to give you the straight engineering facts, minus the sales talk.